TEN, a copper tube pre-insulated with low-density closed cell expanded polyethylene, in compliance with Law 10/91, former Law 373, regarding the design, installation, running and maintenance of thermal systems for buildings, for the purposes of energy consumption control. Ideal for water distribution systems, classified in fire resistance class 1, the coating has been designed in the smallest details to respond excellently to the increasingly more qualified requirements in the design of modern plants. The protective film is corrugated to provide greater adherence to cement mortars and has an excellent resistance to external agents. The coating is odourless, non-toxic and is made without the use of CFC. It is suitable to be used in plants with operating temperatures ranging from -30°C to +95°C. The TEN copper tube is supplied in 50-meter coils (25 meters with Ø 22 mm) marked at intervals also indicating the relative meters. The core of the TEN is the ESENCOR copper tube, providing excellent protection against corrosion, the result of scientific studies and tests that guarantee a considerably lower level of residual carbon than is required by manufacturing standards. |
| INSULATION DENSITY | : | 30 kg/m³ | |||||||||||||||||||||||||||||||||||||||
| THICKNESS OF THE INSULATING SHEATH | : | from 6 to 9 mm | |||||||||||||||||||||||||||||||||||||||
| OPERATING TEMPERATURES | : | -30 °C +95 °C | |||||||||||||||||||||||||||||||||||||||
| THERMAL CONDUCTIBILITY | : | 0.0397 W · mˉ¹ · Kˉ¹ | |||||||||||||||||||||||||||||||||||||||
| RESISTANCE TO FIRE | : | Class 1 (self-extinguishing) | |||||||||||||||||||||||||||||||||||||||
| WRAPPING | : | coils individually wrapped with transparent film to give further protection | |||||||||||||||||||||||||||||||||||||||
| CHARACTERISTICS OF THE ESENCOR COPPER TUBE | |||||||||||||||||||||||||||||||||||||||||
| Alloy | Cu-DHP CW024A (Cu = 99.90% min. – P = 0.015 ÷ 0.040%) | ||||||||||||||||||||||||||||||||||||||||
| Physical state | Annealed | ||||||||||||||||||||||||||||||||||||||||
| Unit tensile strength | 220 MPa/mm² | ||||||||||||||||||||||||||||||||||||||||
| Percentage elongation | 40% | ||||||||||||||||||||||||||||||||||||||||
| Internal cleanliness | C max 0,20 mg/dm² | ||||||||||||||||||||||||||||||||||||||||
| Dimensions and tolerances ¹ | in compliance with standard EN 1057 | ||||||||||||||||||||||||||||||||||||||||
| Internal surface roughness | RA 1/10 micron | ||||||||||||||||||||||||||||||||||||||||
| Linear thermal expansion coefficient | 0.00168 mm/m °C | ||||||||||||||||||||||||||||||||||||||||
| Thermal conductivity at 20 °C | 364 W/m k | ||||||||||||||||||||||||||||||||||||||||
| ¹ Products with marking, dimensional tolerances and various lengths can be prepared on specific Customer request. | |||||||||||||||||||||||||||||||||||||||||
| TABLE OF DIMENSIONS OF THE SILMET TEN COPPER TUBE | |||||||||||||||||||||||||||||||||||||||||
|
dimensions without insulation |
diameter with insulation |
thickness of insulating sheath |
bursting | operating | coil | water content | |||||||||||||||||||||||||||||||||||
| pressure | pressure | length | per meter | ||||||||||||||||||||||||||||||||||||||
| mm | mm | mm | MPa | MPa | m | l/m | |||||||||||||||||||||||||||||||||||
| 10 X 1 | 22 | 6 | 44,88 | 11,22 | 50 | 0,0503 | |||||||||||||||||||||||||||||||||||
| 12 X 1 | 24 | 6 | 37,40 | 9,35 | 50 | 0,0785 | |||||||||||||||||||||||||||||||||||
| 14 X 1 | 26 | 6 | 32,06 | 8,01 | 50 | 0,1131 | |||||||||||||||||||||||||||||||||||
| 16 X 1 | 29 | ||||||||||||||||||||||||||||||||||||||||