The SYSTEM GAS copper tube in Cu DHP 99.9% copper - EN 1057, insulated with sheath in closed cell, expanded polyethylene, is produced with cutting-edge machinery and explicitly made for building gas distribution plants in civil residential buildings and according to the provisions under the UNI CIG 7129 standard for chased in pipes.
Characteristics
The internal air chamber between the copper tube and the coating itself allows gas to exit the building if there are any leaks from the feeding plant.
Silmet SYSTEM GAS is the optimal solution for building chased in gas distribution systems.
The core of the SILMET SYSTEM GAS is the ESENCOR copper tube, providing excellent protection against corrosion, and is the result of scientific studies and tests that guarantee a considerably lower level of residual carbon than that required by manufacturing standards.
Supply
The Silmet SYSTEM GAS copper tube is supplied in 50-metre coils (25 metres with Ø 22 mm) marked at intervals also indicating the relative metres.
The copper tube EN 1057 is marked СЄ as required by EU 305/2011 EU Construction Products Regulation (CPR).
INSULATION DENSITY | 130 kg/m3 |
THICKNESS OF THE INSULATING SHEATH | 6 mm |
USAGE TEMPERATURES | -30 °C +95 °C |
THERMAL CONDUCTIVITY | 0,0397 W · m-1 · K-1 |
RESISTANCE TO FIRE | Class 1 (self-extinguishing) |
WRAPPING | coils individually wrapped with transparent film to give further protection |
Usage and Directives
SYSTEM GAS copper tube is suitable for the following fields of use and with the following references:
Distribution of liquid and gaseous fuels
UNI CIG 7129
Gas systems for the household and similar powered by the distribution network - Design and installation.
Technical sheets
Alloy | Cu-DHP CW024A (Cu = 99,90% min. - P = 0,015 ÷ 0,040%) |
Physical state | Annealed |
Unit tensile strength | 220 MPa/mm2 min. |
Percentage elongation | 40% min. |
Internal cleanliness | C max. 0,20 mg/dm2 |
Dimensions and tolerances | In compliance with standard EN 1057 |
Internal surface roughness | RA 1/10 di micron |
Linear thermal expansion coefficient | 0,00168 mm/m °C |
Thermal conductivity at 20° | 364 W/m · K |
dimensions without insulation | dimensions with insulation | thickness of insulating sheath | bursting pressure | operating pressure | coil length | water content per meter |
12 X 1 | 24 | 6 | 37,4 | 9,35 | 50 | 0,0785 |
14 X 1 | 26 | 6 | 32,06 | 8,01 | 50 | 0,1131 |
15 X 1 | 27 | 6 | 29,92 | 7,48 | 50 | 0,1327 |
16 X 1 | 28 | 6 | 28,05 | 7,01 | 50 | 0,1539 |
18 X 1 | 30 | 6 | 24,93 | 6,23 | 50 | 0,2011 |
22 X 1,5 | 34 | 6 | 30,6 | 7,65 | 25 | 0,2835 |
dimensions Ø x thickness | coil length | coils per pallet | meters per pallet | approx. gross pallet weight | dimensions of pack |
mm | m | n | m | kg | cm |
12 X 1 | 50 | 17 | 850 | 335 | h 220 X Ø 80 |
14 X 1 | 50 | 16 | 800 | 363 | h 220 X Ø 80 |
15 X 1 | 50 | 15 | 750 | 383 | h 220 X Ø 80 |
16 X 1 | 50 | 15 | 750 | 394 | h 220 X Ø 80 |
18 X 1 | 50 | 13 | 650 | 375 | h 220 X Ø 90 |
22 x 1,5 | 25 | 18 | 450 | 456 | h 220 X Ø 90 |
The packs cannot be stacked.
A maximum of 2 packs with a large diameter (h 220 x Ø 90 cm) and available for other coated products, are loaded onto the pallet side-by-side together with a third smaller pallet.
The others can be loaded side-by-side in threes.